Collaborative Information Site

Microbiology

Procedure For Operation And Calibration Of Lab Oven

To lay down the Procedure for Operation and Calibration of Lab Oven. This procedure applies to operation and calibration of lab oven used for sterilization of lab accessories. The responsibility of operation and calibration of lab oven lies with Microbiologist/Analyst.

https://ichapps.com/qms/view/procedure-for-operation-and-calibration-of-lab-oven

continue reading
1 visits |0 Comments

Procedure To Be Followed For The Operation Calibration And Maintenance Of Air Sampler

To lay down the procedure to be followed for the operation, calibration and maintenance of Air sampler. The responsibility of operation and calibration of himedia Air sampler and MAS-100 NT Air sampler lies with Microbiologist / Analyst.

https://ichapps.com/qms/view/procedure-to-be-followed-for-the-operation-calibration-and-maintenance-of-air-sampler

continue reading
1 visits |0 Comments

Procedure For Operation Calibration And Maintenance Of Incubators

To lay down the procedure for operation, calibration and maintenance of incubators. This procedure applies to incubators used in microbiology for incubation at required temperatures respectively with the following details. The responsibility of proper operation, calibration and maintenance of incubators lies with the Microbiologist.

https://ichapps.com/qms/view/procedure-for-operation-calibration-and-maintenance-of-incubators

continue reading
1 visits |0 Comments

Bio Load In Controlled Areas By Using Settle Plates Air Sampling And Contact Plate

To lay down the procedure for environmental monitoring of bio-load in controlled areas by using settle plates, air sampling and contact plate. This procedure applicable to controlled areas like pharma areas at different locations where crystallization, centrifuging, vacuum drying, sifting, blending, micronisation, compaction and packing of finished product are carried out and Microbiology testing area.

https://ichapps.com/qms/view/procedure-for-environmental-monitoring-of-bio-load-in-controlled-areas-by-using-settle-plates-air-sampling-and-contact-plate

continue reading
1 visits |0 Comments

Procedure For Microbial Analysis Of Finished Product (API)

To lay down the procedure for microbial analysis of finished product (API). This procedure applicable to test the total aerobic microbial count and total combined yeast and molds count and to test for the presence of pathogens in any finished product (API).

continue reading
1 visits |0 Comments

Procedure for sampling testing and release of potable water and purified water

To lay down the procedure for sampling, testing and release of potable water and purified water. This procedure applicable to be followed during sampling, testing and release of potable water and purified water. The responsibility of sampling and testing of potable water and purified water lies with the Quality Control analyst and release of potable water and purified water lies with QCD-In charge or his designate.

https://ichapps.com/qms/view/procedure-for-sampling-testing-and-release-of-potable-water-and-purified-water

continue reading
1 visits |0 Comments

Procedure For Investigation Of Out Of Specification (OOS) Results In Microbiology

To lay down the procedure for Investigation of out of specification (OOS) results in Microbiology. This procedure is applicable to Investigation of out of specification (OOS) results in microbial testing of Non-Sterile Products, Water Samples, and Environmental Monitoring carried at Astrix Laboratories Limited, Kazipally.

https://ichapps.com/qms/view/procedure-for-investigation-of-out-of-specification-oos-results-in-microbiology

continue reading
1 visits |0 Comments

Procedure For Conducting The Bacterial Endotoxin Test Of Purified Water And Operation Of Cyclomixer

To lay down the procedure for conducting the Bacterial Endotoxin Test of Purified Water and Operation of Cyclomixer. This procedure applies to testing of bacterial endotoxins for purified water by gel clot method and also applies to operation of cyclomixer. The responsibility of performing the bacterial endotoxin test for purified water and operation of cyclomixer lies with Microbiologist/Analyst.

https://ichapps.com/qms/view/procedure-for-conducting-the-bacterial-endotoxin-test-of-purified-water-and-operation-of-cyclomixer

continue reading
1 visits |0 Comments

Procedure To Be Followed For Cleaning Of Glassware And Sterilization Glassware And Microtips

To lay down the procedure to be followed for cleaning of glassware and sterilization glassware and microtips. This procedure applies to cleaning of glassware and sterilization of glassware and microtips used for microbiological testing. The responsibility of cleaning and sterilization of glassware and microtips lies with Microbiologist/Analyst.

https://ichapps.com/qms/view/procedure-to-be-followed-for-cleaning-of-glassware-and-sterilization-glassware-and-microtips

continue reading
1 visits |0 Comments

Procedure For Isolation Identification And Gram Staining Of Microorganisms

To lay down the Procedure for Isolation,Identification and Gram Staining of Microorganisms. This procedure applies to isolation, identification and gram staining of microorganisms during the course of regular microbiological analysis. The responsibility of isolation, identification and gram staining of microorganisms lies with the Microbiologist/Analyst.

https://ichapps.com/qms/view/procedure-for-isolation-identification-and-gram-staining-of-microorganisms

continue reading
1 visits |0 Comments